Environmental specifications

Trimble recommends using the Alloy receiver within the following environmental operating conditions.

Operating temperature

–40 °C to +65 °C (–40 °F to +149 °F)

To protect the removable Lithium-ION batteries from extreme temperatures, the internal battery charger only charges batteries from –20 °C to +50 °C (–4 °F to +122 °F).

Storage temperature

–40 °C to +80 °C (–40 °F to +176 °F)

Humidity

100% condensing

Shock

 

Operating

40 g per MIL-STD-810G Table 5.16.6-VII

Non-operating

75 g per MIL-STD-810G Table 5.16.6-VII

 

Designed to survive 1 m bench drop

Vibration

 

Operating

MIL-STD-810G Fig. 5.14.6C-1 Category 4

Ingress protection

IP68 Certified per IEC-60529 - waterproof/dustproof