Serial port
Applicable receivers: BD940 | BD940-INS
BD940 evaluation board
|
Item |
Description |
|---|---|
|
Port 1 |
COM 1 is at 0 - 3.3 V TTL. If the integrator needs this port to be at RS-232 level, a proper transceiver powered by the same 3.3 V that powers the receiver must be added. For development using the I/O board, this COM port is already connected to an RS-232 transceiver. This is labeled COM1 on the I/O board. |
|
Port 2 |
COM 2 is at 0 - 3.3 V TTL. This port has RTS/CTS to support hardware flow control. If the integrator needs this port to be at RS-232 level, a proper transceiver powered by the same 3.3 V that powers the receiver must be added. For development using the I/O board, this COM port is already connected to an RS-232 transceiver. This is labeled COM2 on the I/O board. |
|
Port 3 |
COM 3 is at 0 - 3.3 V TTL. If the integrator needs this port to be at RS-232 level, a proper transceiver powered by the same 3.3 V that powers the receiver must be added. For development using the I/O board, this COM port uses a USB serial implementation, see the schematic in USB. This is labeled COM3 on the I/O board. |
|
Port 4 |
COM 4 is at 0 - 3.3 V TTL. This port has RTS/CTS to support hardware flow control. If the integrator needs this port to be at RS-232 level, a proper transceiver powered by the same 3.3 V that powers the receiver must be added. For development using the I/O board, this COM port uses a USB serial implementation, see the schematic in USB. This is labeled COM4 on the I/O board. |
BD940-INS evaluation board
|
Item |
Description |
|---|---|
|
Port 1 |
COM 1 is already at RS-232 level and already has 8 kV contact discharge/15 kV air gap discharge ESD protection. This is labeled Port 3 on the I/O board. |
|
Port 2 |
COM 2 is at 0 - 3.3 V TTL. This port has RTS/CTS to support hardware flow control. If the integrator needs this port to be at RS-232 level, a proper transceiver powered by the same 3.3 V that powers the receiver must be added. For development using the I/O board, this COM port is already connected to an RS-232 transceiver. This is labeled UHF Port 2 on the I/O board. |