Default settings
Applicable receivers: AX940 | AX940i | BD940 | BD940-INS | BD970 | BD982 | BX940 | BX982
All settings are stored in application files. The default application file, Default.cfg, is stored permanently in the receiver, and contains the factory default settings. Whenever the receiver is reset to its factory defaults, the current settings (stored in the current application file, Current.cfg) are reset to the values in the default application file.
These settings are defined in the default application file.
|
Function |
Settings |
Factory default |
|---|---|---|
|
SV Enable |
- |
All SVs enabled |
|
General Controls |
Elevation mask |
10° |
|
PDOP mask |
99 |
|
|
RTK positioning mode |
Low Latency |
|
|
Motion |
Kinematic |
|
|
Ports |
Baud rate |
38,400 |
|
Format |
8-None-1 |
|
|
Flow control |
None |
|
|
Input Setup |
Station |
Any |
|
NMEA/ASCII (all supported messages) |
|
All ports Off |
|
Streamed Output |
|
All types Off |
|
Offset=00 |
||
|
RT17/Binary |
|
All ports Off |
|
Reference Position |
Latitude |
0° |
|
Longitude |
0° |
|
|
Altitude |
0.00 m HAE |
|
|
Antenna |
Type |
Unknown |
|
Height (true vertical) |
0.00 m |
|
|
Measurement method |
Antenna Phase Center |
|
|
1PPS |
|
Enabled |
|
Event Ports |
|
Disabled |
If a factory reset is performed, the above defaults are applied to the receiver.
When receivers are factory reset, if they had a static IP address configured, the receiver is returned to a DHCP mode. Security is enabled (with a default login of admin and the password of password), or for units with Enhanced Security enabled, the password will be reset to the serial number of the unit (which you must change at first login).
To perform a factory reset:
-
From the web interface, select Receiver Configuration / Reset and then clear the Clear All Receiver Settings option.
-
Send the Command 58h with a 03h reset value. Refer to receiverhelp.trimble.com/oem-gnss/ICD_Pkt_Command58hRESETRCVR.html.
-
Send the Command 58h with a 03h reset value.
-
Use the WinFlash software and select the Reset to factory default option.
-
Use the Configuration Toolbox utility and from the Communications menu, select Reset Receiver. Select both the Erase Battery-Backed RAM and Erase File System options.