Communication specifications
Applicable receivers: | BX1092i
|
Feature |
Specification |
|---|---|
|
Communications |
1 × LAN port Supports links to 10BaseT/100BaseT networks. All functions are performed through a single IP address simultaneously including web interface access and data streaming. |
|
2 × RS-232 ports Baud rates up to 921,600 1 × USB 2.0 port 1 × CAN bus 2 × event ports NOTE – The multiplexed port on the BX1092i cannot be configured. |
|
|
Receiver position update rate |
1 Hz, 2 Hz, 5 Hz, 10 Hz, 20 Hz, 50 Hz, and 100 Hz positioning for GNSS and INS |
|
Correction data input |
CMR, CMR+™, sCMRx, RTCM 2.0 to 2.4, RTCM 3.x, 3.2, 3.3 |
|
Correction data output |
CMR, CMR+, sCMRx, RTCM 2.1 to 2.4, RTCM 3.x, 3.3 |
|
Data outputs |
NMEA-0183, 1PPS & ASCII Time Tags, Binary GSOF, Binary RT17 / RT27, BINEX, NMEA2000 (over CAN when available) |
|
Network protocols |
|
|
Control software |
Web browser: Internet Explorer, Firefox, Safari, Opera, Google Chrome |