Ethernet
Applicable receivers: BD940 | BD940-INS | BD990 | BD992 | BD992-INS | BX940
The receiver contains the ethernet MAC and PHY, but requires external magnetics
Since ethernet functionality typically increases the receiver power consumption by approximately 10%, the BD940 receiver module, the BD940-INS receiver module and the BX940 receiver enclosure shuts down the ethernet controller if no ethernet devices are connected within two minutes. You can disable this setting in the Network Configuration / Ethernet Configuration menu.
Isolation transformer selection
|
Parameters |
Value |
Test condition |
|---|---|---|
|
Turns ratio |
1CT:1CT |
|
|
Open-circuit inductance (min.) |
350 uH |
100 mV, 100 kHz, 8 mA |
|
Leakage inductance (max.) |
0.4 uH |
1 MHz (min.) |
|
DC resistance (max.) |
0.9 Ohms |
|
|
Insertion loss (max.) |
1.0 dB |
0 MHz to 65 MHz |
|
HiPot (min. |
1500 Vrms |
|